Inspection History Details
Inspection Status: Approved
Inspection History: SITE - SEWER
Permit Number - T06PL00114
Inspection Description - SITE - SEWER
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/30/2007 | SITE - SEWER | Approved | REVISED APPROVED PLAN ON SITE | |
01/17/2007 | SITE - SEWER | Partial Approval | IVRS - Inspection :* VACUUM TEST PRIVATE MANHOLE #1 20 SECONDS NO DROP 1/10 DROP AT 34 SECONDS OK |
|
01/02/2007 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* FRANK, PLEASE PROVIDE A CONTACT NUMBER FOR COORDINATION OF TEST. |
|
12/28/2006 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER CONTRACTOR |
|
12/13/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* - 8" SDR FROM PUBLIC MANHOLE #8 WITH 8" DUCTILE PER PLAN TO PRIVATE MANHOLE #1, BEDDING, LAYING, TRACER, SHADING, BASE OK - AIR TEST OK - NEED VACUUM TEST OF PRIVATE MANHOLE #1 & AUTHORIZATION TO DISCHARGE. |
|
12/12/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* FROM NEW MANHOLE #8 (PUBLIC) UPSTREAM 11' PVC SDR 35 TRANSITION TO 8" DUCTILE 20' TRANSITION PAD ADAPTER BACK TO SDR 35 BEDDING, LAYING OK INSTALL TRACER WIRE OK TO CENTER LOAD & CONTINUE LAYING. SHALL SEE CONTINUATION OF PIPING, AIR TESTING, VACUUM TESTING OF NEW PRIVATE MANHOLE #1 WITH AUTHORIZATION TO DISCHARGE AT LATER DATE. |
|
12/11/2006 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELLED |
|
12/04/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* THIS INSPECTION FOR PRE-CONSTRUCTION MEETING REVISED PLAN ON SITE ADDITION OF HCS OUT OF NEW PRIVATE MANHOLE #1 SHALL REQUIRE CITY APPROVED REVISED PLAN, REDLINE SHALL BE ON SITE FOR THIS ADDITION TO PROCEED WITH THIS WORK. PIPING TO BE INSTALLED PER PIMA COUNTY 2003 WASTEWATER STANDARDS WITH INDEPENDENT INSPECTION FOR PCDEQ AIR TEST ON PIPING, VACUUM TESTING OF NEW MANHOLE AT LATER DATE SHALL PROVIDE TRACER WIRE ON ALL PRIVATE SEWER. |