Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T06PL00103
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/27/2006 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
01/26/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 7 PSI 30 PSI GAUGE POSSIBLE LEAK. GAUGE IS REQUIRED TO HAVE 1/10 POUND INCREMENTATION IN ORDER TO ENSURE THAT NO LEAKS EXIST WITHIN THE 10 MIN INSPECTION. TEMPERATURE & PRESSURE RELIEF VALVE MUST TERMINATE VERTICALLY 6"-24" ABOVE GROUND, WITHOUT THREADS. USE OF THREAD PROTECTOR AS A COUPLING IS PROHIBITED. LISTED FITTINGS REQUIRED. REMOVE UNECESSARY TEES IN RUN NEAR METER |
|
01/20/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* A RESIDENCE MUST HAVE HOT WATER A WATER HEATER SHALL BE INSTALLED PRIOR TO ALLOWING GAS SERVICE IF AN ELECTRIC WATER HEATER IS INSTALLED A SEPARATE PERMIT WOULD BE REQUIRED. REPRESSURE TEST AND CALL FOR INSPECTION WHEN READY |