Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/27/2006 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* 1. CORRECTIONS MADE OK 2. OK FOR GAS 3. UCC LEFT AT METER SW GAS 889-1888 |
|
| 02/14/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* - CORRECT VENT CONNECTOR FROM WATER HEATER -- USE SINGLE WALL, SECURE W/SCREWS - RAISE DOUBLE WALL VENT TERMINATION TO 3' ABOVE COOLER - PROVIDE ELECTRICAL BONDING - PROVIDE FLASHING AT ROOF PENETRATION - PROVIDE WEATHER RESISTANT PIPE SUPPORTS - PROVIDE SUPPORT OF PIPING AT FURNACE |
|
| 02/10/2006 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* SEE NOTES FROM 02/06/06 |
|
| 02/06/2006 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :*T & P RELIEF DRAIN TO BE GRAVITY DRAIN TO OUTSIDE. 201 N. STONE PETITION OF APPEAL FOR A VARIANCE TO THE LOCATION INSTALL 1 1/2" PAN WATER UNDER WATER HEATER DRAIN T & P RELIEF TO PAN INSTALL RELIEF VALVE ON COLD HOSE BIBB ( 125 LBS) |
|
| 01/31/2006 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :*NO TEST SUPPORT ROOF TOP PIPING INSTALL T :& P RELIEF DRAIN |