Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
02/27/2006 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
1. CORRECTIONS MADE OK
2. OK FOR GAS
3. UCC LEFT AT METER
SW GAS 889-1888
02/14/2006 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
- CORRECT VENT CONNECTOR FROM WATER HEATER -- USE SINGLE WALL, SECURE W/SCREWS
- RAISE DOUBLE WALL VENT TERMINATION TO 3' ABOVE COOLER
- PROVIDE ELECTRICAL BONDING
- PROVIDE FLASHING AT ROOF PENETRATION
- PROVIDE WEATHER RESISTANT PIPE SUPPORTS
- PROVIDE SUPPORT OF PIPING AT FURNACE
02/10/2006 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
SEE NOTES FROM 02/06/06
02/06/2006 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*T & P RELIEF DRAIN TO BE GRAVITY DRAIN TO OUTSIDE.
201 N. STONE PETITION OF APPEAL FOR A VARIANCE TO THE LOCATION
INSTALL 1 1/2" PAN WATER UNDER WATER HEATER
DRAIN T & P RELIEF TO PAN
INSTALL RELIEF VALVE ON COLD HOSE BIBB ( 125 LBS)
01/31/2006 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*NO TEST
SUPPORT ROOF TOP PIPING INSTALL T :& P RELIEF DRAIN