Permit: T06PL00044

Parcel: 122110170


Addresses:

4108 E DRYDEN LN

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESS TEST FNL

Date Description Inspector Results Comments
01/26/2006 PLUMBING - GAS PRESS TEST FNL Approved IVRS - Inspection :*
01/17/2006 PLUMBING - GAS PRESS TEST FNL Denied IVRS - Inspection :
See detailed listing on site.| 999*GAS SHUT OFF VALVE SHALL BE LOCATED 3" -0" OF DEVELOPED LENGHT MAX FOR WATER HTR SUPPLY
01/13/2006 PLUMBING - GAS PRESS TEST FNL Denied IVRS - Inspection :
See detailed listing on site.| 999*
36" X 3/8" 10 GAS GLEX AT FURNACE IS NOT LARGE ENOUGH FOR 77000 BTU FURNACE
PROVIDE NEW FLEX AT WATER HEATER - INSTALL WITHOUT KINK
T&P SAFETY VALVE ON WATER HEATER IS LEAKING
SUPPORT PIPING BEHIND FURNACE