Permit: T06PL00025

Parcel: 118220060


Addresses:

231 W 22ND ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/03/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
OK FOR GAS
CALL SW GAS 889-1888
01/30/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
10 PSI TEST REQUIRED. GAUGE MUST HAVE 1/10 TH PSI INCREMENTATION
AGA VALVES REQUIRED
WATER HEATER IS REQUIRED TO BE PROTECTED BY A WEATHERPROOF ENCLOSURE
T&P MUST TERMINTATE 6" ABOVE GROUND
EXTERIOR FLUE PIPING IS REQUIRED TO BE DOUBLE WALL B VENT AND SHALL TERMINATE 1' ABOVE ANY VERTICAL SURFACE WITH A LISTED VENT CAP.
DO NOT TAPE JOINTS AT SINGLE TO DOULBE WALL CONNECTIONS - USE LISTED FITTINGS. THREAD PROTECTORS ARE NOT ACCEPTED
USE WEATHER RESISTANT PIPING SUPPORTS
INSTALL NEW FLEXES AT APPLIANCE CONNECTIONS
RECALL FOR INSPECTION WHEN READY