Inspection History Details
Inspection Status: Denied
Inspection History: PLUMBING - FINAL
Permit Number - T06PL00024
Inspection Description - PLUMBING - FINAL
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/10/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST ADDRESS 2) PRESSURE TEST REQUIRED 3) ROOF FLASHINGS REQUIRED 4) PROVIDE PROPER SIZED GAS FLEX AT FURNACE AND WATER HEATER 5) PROVIDE VENTING OF WATER HEATER 6) SECURE VENT CONNECTOR AT FURNACE AND PROVIDE DBL WALL B-VENT THROUGH ROOF AND TERMINATE ABOVE COOLER 7) BONDING OF GAS LINE REQUIRED 8) TERMINATE T-P VALVE WITH APPROVED MATERIAL 6"-24" ABG 9) PIPING BEHIND STOVE WILL NOT ALLOW STOVE TO BE PUSHED IN TO PLACE-CORRECT |