Permit: T06PL00011

Parcel: 138140080


Addresses:

449 W BILBY RD

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
01/12/2006 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
01/10/2006 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DBL WALL B VENT REQUIRED ABOVE ROOF (CANNOT CHANGE FROM DBL WALL TO SINGLE WALL)
2) GAS PIPING BEHIND STOVE WALL NOT ALLOWED. STOVE TO BE PUSHED BACK INTO PLACE
3) SEAL WALL PENETRATIONS
4) OUTLET OF GAS METER SHOULD BE TEMPORARILY COVERED TO PREVENT CONTAMINATION
01/05/2006 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 14 PSI PRESSURE DROPING-CHECK FOR LEAKS
2) T & P SAFETY VALVE MUST GRAVITY DRAIN TO EXTERIOR
3) BONDING OF GAS LINE REQUIRED
4) REMOVE TAPE AT DBL WALL VENT
5) INSTALL TEE AT FURNACE AND WATER HEATER
6) AGA VALVES REQUIRED
7) FLU PIPING MUST BE 3' ABOVE FORCED AIR INLET OF COOLER WITHIN 10'
8) RECALL FOR INSPECTION