Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/12/2006 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 01/10/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DBL WALL B VENT REQUIRED ABOVE ROOF (CANNOT CHANGE FROM DBL WALL TO SINGLE WALL) 2) GAS PIPING BEHIND STOVE WALL NOT ALLOWED. STOVE TO BE PUSHED BACK INTO PLACE 3) SEAL WALL PENETRATIONS 4) OUTLET OF GAS METER SHOULD BE TEMPORARILY COVERED TO PREVENT CONTAMINATION |
|
| 01/05/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 14 PSI PRESSURE DROPING-CHECK FOR LEAKS 2) T & P SAFETY VALVE MUST GRAVITY DRAIN TO EXTERIOR 3) BONDING OF GAS LINE REQUIRED 4) REMOVE TAPE AT DBL WALL VENT 5) INSTALL TEE AT FURNACE AND WATER HEATER 6) AGA VALVES REQUIRED 7) FLU PIPING MUST BE 3' ABOVE FORCED AIR INLET OF COOLER WITHIN 10' 8) RECALL FOR INSPECTION |