Permit: T06OT03160

Parcel: 116012170


Addresses:

2302 N CAMINO MATEO

Inspection Status: Approved

Inspection History: CERTIFICATE OF OCCUPANCY

Date Description Inspector Results Comments
01/10/2007 CERTIFICATE OF OCCUPANCY Approved IVRS - Inspection :*
12/12/2006 CERTIFICATE OF OCCUPANCY Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. REMOVE DOUBLE KEYED DEADBOLT ON REAR DOOR
2. PVC IS NOT APPROVED FOR ABOVE GROUND NOR INTERIOR USE. REPLACE WITH APPROVED MATERIAL (1/2" TO OUTSIDE HOSE BIBB)
3. FEMALE SCHEDULE 40 PIPE NIPPLES (THREADED) ARE NOT ALLOWED FOR TRANSITION TO M.I.P
4. DO NOT USE GALVANIZED NIPPLES ON COPPER PIPE.
5. EXTERIOR HOSE BIBBS REQUIRE ANTI-SIPHON DEVICES
6. BUILD A CHASE FOR ROMEX WIRING
FLOOR TO CEILING & ALONG CEILING
2X4 WITH SHEETROCK