Permit: T06OT03055

Parcel: 13315316A

Inspection Status: Approved

Inspection History: CERTIFICATE OF OCCUPANCY

Date Description Inspector Results Comments
01/16/2007 CERTIFICATE OF OCCUPANCY Approved IVRS - Inspection :*
ALL AREAS BELOW HAVE BEEN CONNECTED
11/27/2006 CERTIFICATE OF OCCUPANCY Not ready for Inspection IVRS - Inspection :*
1. ALL INDIRECT WASTE TO TERMINATE 1" ABOVE FLOOD RIM OF FLOOR SINKS.
2. PROVIDE CURRENT CERTIFICATION FOR BACKFLOW DEVICES (BEHIND BAR)
3. THUMB ACTIVATED DEAD-BOLT REQUIRED AT OFFICE
4. SPLIT FRONT TOILET SEATS REQUIRED ON ALL TOILETS
5. USE CORRECT FITTINGS FOR HAND SINK DRAIN IN KITCHEN, ALSO BLOCK STAND PIPE IN WASHER BOX.
6. FRYER TO BE 6" UNDER HOOD.
7. EXIT SIGN TO BE WORKING.