Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/24/2007 | SIGN SHOP | Approved | IVRS - Inspection :* | |
07/16/2007 | SIGN SHOP | Partial Approval | IVRS - Inspection :* 1. NEED CITY STICKERS OK MONUMENTS ON SITE |
|
06/25/2007 | SIGN SHOP | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SPLICES IN PULL BOXES TO BE FOR WET LOCATION - 110.3 2. PLEASE UNCOVER RACEWAY FOR UNDERGROUND INSPECTION AS DISCUSSED 3. MARKING LABELS ARE NEEDED -- 600.4 4. SWITCH TO BE EXTERNALLY OPERABLE -- 600.6 |
|
02/26/2007 | SIGN SHOP | Not ready for Inspection | IVRS - Inspection :* |