12/29/2006 | SIGN SHOP | Approved | IVRS - Inspection :* | |
12/28/2006 | SIGN SHOP | Partial Approval | IVRS - Inspection :* 1) OK SIGN |
|
12/22/2006 | SIGN SHOP | Not ready for Inspection | IVRS - Inspection :* 1. MAINTAIN GTO CLEARANCES - GROUNDED SURFACES AND OTHER CABLES. 2. A WALKWAY IS NEEDED PER 600.21 3. A SERVICE LIGHT IS NEEDED PER 210.70 4. SWITCH TUBE IN SIGHT OF SIGN OR CAPABLE OF BEING LOCKED OUT -- 600.6 5. INSTALL MARKING LABEL -- 600.4 |