Inspection History Details
Inspection Status: Approved
Inspection History: SIGN SHOP
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/08/2008 | SIGN SHOP | Approved | IVRS - Inspection :* | |
| 04/14/2008 | SIGN SHOP | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. FILL OUT MARKING LABEL 2. BOND RACEWAY ENCLOSURES 3. LED DRIVER GOOD FOR MAX AMBIENT TEMP OF 40 DEG. C 4. VERIFY LED MODULES - NUMBERS NOT IN SAM |