Permit: T06OT02187

Parcel: 113052570

Inspection Status: Approved

Inspection History: SIGN SHOP

Permit Number - T06OT02187

Inspection Description - SIGN SHOP

Inspection Status - Approved

Date Description Inspector Results Comments
01/26/2007 SIGN SHOP Approved IVRS - Inspection :*
01/25/2007 SIGN SHOP Partial Approval IVRS - Inspection :*
1. GROUNDING/BONDING OF LETTER NOT ALLOWED TO BE SOLDER - 250.8 NEC
18.6 VL 48
01/23/2007 SIGN SHOP Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. A MARKING LABEL IS NEEDED ON SIGN 600.4
2. WEATHERPROOF WIRING TO LED LETTERS
3. BOND METAL LED LETTERS
4. TIGHTEN LOOSE FITTINGS
5. RACEWAY TO BE COMPLETE - 4 SIDES
6. BOND RACEWAY
7. POWER SUPPLIES FOR INDOOR ONLY
8. POWER SUPPLY TO BE ACCESSIBLE
9. NO PLANS OR PERMIT ON SITE
10. DO NOT ENERGIZE SIGN UNTIL FINALED BY ELECTRICAL INSPECTOR.
09/29/2006 SIGN SHOP Not ready for Inspection IVRS - Inspection :*