Permit: T06OT01913

Parcel: 10607010B

Inspection Status: Approved

Inspection History: CERTIFICATE OF OCCUPANCY

Date Description Inspector Results Comments
08/16/2006 CERTIFICATE OF OCCUPANCY Approved IVRS - Inspection :*
08/10/2006 CERTIFICATE OF OCCUPANCY Not ready for Inspection IVRS - Inspection :*
ALL PLUMBING FITTINGS MUST MEET CODE
YOU MUST USE LISTED PARTS NOT HOMEMADE CUTOUTS
YOU CANNOT TIE INTO A TRAP ARM WITH ANOTHER DRAINAGE PIPE
LICENSED PLUMBER WITH COMMERCIAL KITCHEN EXPERIENCE REQUIRED.
07/31/2006 CERTIFICATE OF OCCUPANCY Denied HOOD, EXHAUST DUCT AND BLOWER HAVE NO INTEGRITY
NOTED CHANGE, DOUBTFUL
OBSOLETE CHEM./ANSUL SYSTEM
07/27/2006 CERTIFICATE OF OCCUPANCY Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. 12" ADDRESS DISPLAY REQUIRED WITH 3" SUITE #
2. PLANS AND PERMITS REQUIRED FOR ENCLOSED OUTDOOR PATIO AREA.
3. REMOVE SURFACE MOUNTED THROW BOLTS FROM IDENTIFIED EXITS.
4. SPLIT FRONT TOILET SEATS ARE REQUIRED IN RESTROOMS
5. I WILL NEED MECHANICAL INSPECTOR TO VERIFY HOOD COMPLIANCE.
6. DRAIN ASSEMBLIES FROM HAND SINKS ARE NOT INSTALLED PER CODE. DISH SINK DRAIN ASSEMBLY NOT PER CODE.
HAVE PROFESSIONAL COMMERCIAL KITCHEN PLUMBING CONTRACTOR EVALUATE SYSTEM REPAIR.
7. CLEAN OUTS REQUIRED AT SINKS
8. RPA BACKFLOW REQUIRED FOR CARBONATOR
9. TESTABLE DOUBLE/CHECK VALVE OR GREATER BACKFLOW PROTECTION REQUIRED FOR ICE MAKER.