Inspection History Details
Inspection Status: Approved
Inspection History: CERTIFICATE OF OCCUPANCY
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/10/2006 | CERTIFICATE OF OCCUPANCY | Approved | IVRS - Inspection :* | |
| 08/09/2006 | CERTIFICATE OF OCCUPANCY | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. MINIMUM 12" ADDRESS DISPLAY REQUIRED PER PIMA COUNTY ORDINANCE. 2. YOU MAY NOT MIX MATERIALS IN DRAIN SYSTEM USE ABS FOR ALL DRAIN PIPE & FITTINGS. ALSO, USE CORRECT GLUE FOR ABS. 3. SANITIZER SINK MUST GO TO INDIRECT WASTE (FLOOR SINK) 4. USE CORRECT COMBO/CLEANOUT AT DISH STATION 5. PROPERLY SUPPORT ALL PIPING TO HAND SINKS; DO NOT MIX PVC & ABS; USE CORRECT GLUE 8" HORIZONTAL WET VENT WILL BE ALLOWED TO REMAIN. 6. INSTALL GRATE OVER FLOOR DRAIN IN WALK-IN 7. REMOVE SURFACE MOUNTED LATCH ON OFFICE DOOR. 8. INSTALL RESTROOM SIGNS. |