Permit: T06OT01597

Parcel: 105102430

Inspection Status: Approved

Inspection History: SIGN SHOP

Date Description Inspector Results Comments
07/25/2006 SIGN SHOP Approved IVRS - Inspection :*
07/12/2006 SIGN SHOP Not ready for Inspection IVRS - Inspection :*
1. ISOLATE POWER TO SWITCH
2. GROUND JUNCTION BOXES
3. GROUND RACEWAY - SHEET METAL SCREWS NOT ALLOWED FOR GROUNDING.
4. REPLACE DAMAGED WIRE NUTS.
5. IF M/C CABLE IS USED IT MUST TERMINATE TO A BOX & FITTING PER MANUFACTURER.
6. DO NOT CROSS GTO CABLES
7. PLEASE REVISE PLANS FROM ELECTRODE HOUSINGS TO DOUBLEBACKS.
8. DO NO ENERGIZE SIGN UNTIL FINALED BY ELECTRICAL INSPECTOR.