Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T06OT01572
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/12/2006 | BUILDING - FINAL | Approved | ||
09/22/2006 | BUILDING - FINAL | Denied | 1. POST 15" ADDRESS DISPLAY PER PIMA COUNTY ZONING ORDINANCE. 2. PROVIDE FLOOR PLAN. 3. ANY DELETED PLUMBING MUST BE PROPERLY CAPPED. 4. PROPERLY CAULK W.C @ FLOOR AND EXTEND FLOOR AT RESTROOM UP 6" OF WALL WITH HARD, IMPERMEABLE SURFACE. 5. DELETE DRAIN EXTENDED OUT OF CLEANOUT AT LAVATORY 6. CAULK LAVATORY AT WALL. 7. LEVER HANDLE, "NO KNOWLEDGE" HARDWARE REQUIRED AT RESTROOM. 8. ACCESSIBLE SIGNAGE REQUIRED @ RESTROOM. 9. INSULATION KIT REQUIRED ON LAVATORY DRAIN & HOT WATER LINE. 10. FLUSH HANDLE TO BE ON WIDE SIDE OF W.C |