Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/08/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 04/27/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* COMPLETE THE INSTALLATION OF HB VACUUM BREAKERS PROVIDE ACCESS TO OR EXPOSE PIPING IN WALL AT LAUNDRY SINK. TRAP ARM MOVES IN AND OUT OF THE WALL BY ABOUT 4". SOMETHING IS NOT RIGHT ABOUT THIS. ALSO THE ABS PIPING IS NEW. IF THIS PIPING WAS NOT INSTALLED UNDER A PERMIT IT WOULD HAVE TO BE PERMITTED OR REMOVED. |
|
| 04/19/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* TOILET NOT CAULKED OPEN FRONT SEAT REQUIRED HB VAC BREAKER REQUIRED IN RESTROOM WATER HEATER ABOVE CEILING REQUIRES A DRAIN PAN W/DRAIN EXPANSION TANK REQUIRED T&P RELIEF SHALL GRAVITY DRAIN TO OUTSIDE P TRAP REQUIRED AT LAUNDRY SINK DRIP ON ANGLE STOP |
|
| 04/17/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. THIS IS THE SECOND TIME YOU HAVE SCHEDULED AN INSPECTION AND THE DOOR HAS BEEN LOCKED. 2. CONTINUED "NOT READY" MAY RESULT IN A REINSPECTION FEE. 3. PLEASE LEAVE A NAME AND CONTACT NUMBER WHEN SCHEDULING INSPECTIONS. |
|
| 04/14/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* DOOR LOCKED -- NO ACCESS |