Inspection Status: Approved
Inspection History: SIGN ELECTRIC
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/15/2006 | SIGN ELECTRIC | Approved | IVRS - Inspection :* | |
| 07/28/2006 | SIGN ELECTRIC | Not ready for Inspection | IVRS - Inspection :* MEET WITH CONTRACTORS TO DISCUSS WORK. |
|
| 07/13/2006 | SIGN ELECTRIC | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. USE AN APPROVED JUNCTION BOX DISCONNECT NOT A JUNCTION BOX TIME CLOCK NOT A JUNCTION BOX 2. SUPPORT CONDUIT AS PER CODE 3. ONLY THE NUMBER OF CONDUCTORS PER TERMINAL AS LISTED BY MANUFACTURER TIME CLOCK. 4. DISCONNECT SWITCH PER 600.6 IS NEEDED -- EXTERNALLY OPERATED. |
|
| 06/19/2006 | SIGN ELECTRIC | Partial Approval | IVRS - Inspection :* |