Date Description Inspector Results Comments
08/11/2008 SIGN ELECTRIC Approved IVRS - Inspection :*
08/06/2008 SIGN ELECTRIC Not ready for Inspection IVRS - Inspection :*
1) NEED A LED PAINT DETAIL NOT JUST WORDING
05/21/2008 SIGN ELECTRIC Partial Approval IVRS - Inspection :*
05/16/2008 SIGN ELECTRIC Partial Approval IVRS - Inspection :*
FINISH AS DISCUSSED
05/05/2008 SIGN ELECTRIC Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspectio
05/01/2008 SIGN ELECTRIC Denied IVRS - Inspection :
See detailed listing on site.| 999*
01/12/2007 SIGN ELECTRIC Not ready for Inspection IVRS - Inspection :*
ROOF:
1. SWITCHES TO BE LOCKABLE
2. TIGHTEN HIGH VOLTAGE CONNECTIONS

DRIVE THRU:
1. SECURE COVERS
2. TIGHTEN LOOSE FITTINGS
3. POWER SUPPLIES MARKED "IN DOOR ONLY"
4. NEED SWITCH PER 600.6

FINISH PREVIOUS ITEMS 1, 5, 7, 8