Inspection History Details
Inspection Status: Approved
Inspection History: SIGN SHOP
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/11/2008 | SIGN SHOP | Approved | IVRS - Inspection :* | |
| 08/06/2008 | SIGN SHOP | Not ready for Inspection | IVRS - Inspection :* | |
| 05/21/2008 | SIGN SHOP | Partial Approval | IVRS - Inspection :* PLANS DO NOT HAVE LED LIGHTS THAT ARE INSTALLED |
|
| 05/16/2008 | SIGN SHOP | Partial Approval | IVRS - Inspection :* FINISH AS DISCUSSED |
|
| 05/05/2008 | SIGN SHOP | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspectio NO WORK PROGRESS PLEASE PAY REFEE BEFORE NEXT INSPECTION |
|
| 05/01/2008 | SIGN SHOP | Denied | IVRS - Inspection : See detailed listing on site.| 999* DRIVE THRU: 1. SECURE ENCLOSURE TO WALL 2. NEED ELECTRIC DETAIL FOR DRIVE THRU ARROWS (#1 OF 8/21/06) ROOF: WEST SIGN 1. NEED ACCESS |
|
| 01/12/2007 | SIGN SHOP | Not ready for Inspection | IVRS - Inspection :* | |
| 08/21/2006 | SIGN SHOP | Not ready for Inspection | IVRS - Inspection :* 1. NEED ELECTRIC DETAILS FOR RACEWAY SIGN, DRIVE THRU ARROW. 2. POWER NOT TO ENTER THROUGH COVER 3. SECURE JUNCTION BOX 4. SEAT SEALTITE INTO FITTING 5. BOND RACEWAYS 6. PROTECT GTO FROM SHARP EDGES OF PASS THROUGH'S 7. TIGHTEN LOOSE SEAL TITE FITTINGS 8. CLOSE SPLICE BOX COVERS 9. SUPPORT TRANFORMER BOX TO BUILDING |