Permit: T06OT00508

Parcel: 11206009A


Addresses:

2782 N CAMPBELL AV


Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T06OT00508

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/06/2006 MECHANICAL - FINAL Approved IVRS - Inspection :*
05/22/2006 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE A PERMIT FOR THE NEW A/C UNIT ON THE ROOF.
DO NOT TERMINATE CONDENSATE INTO A HOLE DRILLED INTO A SEWER VENT.
MUST TERMINATE TO AN APPROVED LOCATION.
PROVIDE A FRESH AIR INTAKE.
MARK THE UNIT DATA PLATE W/PROPER HEAT STRIP INSTALLED & FUSE ACCORDINGLY.
CONDENSATE INTO SEWER VENTS IS NO LONGER ACCEPTABLE.
YOU CAN PUMP THE WATER INDIRECTLY INTO THE TOP OF A SEWER VENT OR DOWN TO THE LAV. TAILPIECE.