Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06OT00437

Parcel: 13214024B


Addresses:

880 E BENSON HY


Inspection Status: Approved

Inspection History: CERTIFICATE OF OCCUPANCY

Permit Number - T06OT00437

Inspection Description - CERTIFICATE OF OCCUPANCY

Inspection Status - Approved

Date Description Inspector Results Comments
03/08/2006 CERTIFICATE OF OCCUPANCY Approved IVRS - Inspection :*
02/21/2006 CERTIFICATE OF OCCUPANCY Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. CONNECT BACKFLOW DEVICES TO SODA AND ICE MACHINES
2. ATMOSPHERE VACUUM BREAKERS REQUIRED ON HOSE BIBS -- NOT PLASTIC CAPS
02/16/2006 CERTIFICATE OF OCCUPANCY Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. AVB REG. ON EXTERIOR HOSE BIBS & HOSE BIBS IN GARAGE
2. COVER EXTERIOR PLUG RECEPTACLES.
3. STOP LEAKS FROM COOLER AND HOSE BIBS
4. PROVIDE BACKFLOW CERTIFICATION
5. SUPPORT CM PIPE EVERY 6'
6. YOUR PLAN HAS SEPARATE MENS & WOMENS RESTROOMS WITH EXITS TO OUTSIDE. YOU WILL REQUIRE A T.I PERMIT TO BLOCK MENS ROOM DOOR, DEMO INTERIOR WALL, DOME TOILET, SINK, ETC AND TURN ROOM INTO STORAGE.
7. YOU REQUIRE A REVERSE PRESSURE BACKFLOW DEVICE FOR SODA MACHINE, CARBONATOR AND WATER SUPPLY.
02/15/2006 CERTIFICATE OF OCCUPANCY Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO PLANS/PERMIT ON SITE
2) DOOR LOCKED-NO ACCESS