Inspection Status: Approved
Inspection History: CERTIFICATE OF OCCUPANCY
Permit Number - T06OT00010
Inspection Description - CERTIFICATE OF OCCUPANCY
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/27/2010 | CERTIFICATE OF OCCUPANCY | Approved | IVRS - Inspection :* 1) APPROVED FOR C OF O |
|
02/08/2006 | CERTIFICATE OF OCCUPANCY | Denied | IVRS - Inspection : See detailed listing on site.| 999*SIGN OVER FRONT DOOR " DOOR TO REMAIN UNLOCKED..." REQUIRES 1" TALL LETTER MINIMUM RESTROOM & THERAPY ROOM REQUIRE LEVER HANDLE " NO KNOWLEDGE HARDWARE" ACCESSIBLE SIGNAGE REQUIRED FOR RESTROOM LAVATORY IN RESTROOM REQURES 27" CLEAR KACE SPACE UNDERNEATH AND LEVER HANDLES FOR FAUCET YOU NEED A PERMIT FOR FOOT SPA IT HAS NOT BEEN INSTALLED PER CODE AND THEREFORE IS A HELTH HAZARD TRPRU DRAIN ON WATER HEATER MUST FLOW DOWNHILL A MINIMUM OF 1/4" PER FOOT. |
|
02/03/2006 | CERTIFICATE OF OCCUPANCY | Not ready for Inspection | IVRS - Inspection :* NEED TO SEE INSIDE MASSAGE THERAPY ROOM |
|
01/27/2006 | CERTIFICATE OF OCCUPANCY | Not ready for Inspection | IVRS - Inspection :*RECALL FOR 1/30/06 |