Permit: T06ME00750

Parcel: 113091180


Addresses:

834 E SEQUOYAH ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
03/06/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
CORRECTIONS HAVE BEEN MADE
OK TO BACKFILL TRENCH
01/10/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
INSULATE ALL SIDES & TOP OF EXPOSED DUCT WORK
IN FURNACE CLOSET. USE MIN. 1 1/2" FIBERGLASS
INSULATION WITH VAPOR BARRIER.
PLASTIC CONDUIT REQUIRES MIN. 18" BURIAL DEPTH.
12/28/2006 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE PROTECTION AT REFER LINE PENETRATION THRU COIL CABINET
2) INSULATE BARE SHEET METAL ON FURNACE
3) EXPOSE ELECTRIC CONDUIT AND REFER LINES BURIED. PROVIDE TRACER WIRE FOR NON METALLIC CONDUIT. NEED TO SEE PROPER BURIAL DEPTCH