Permit: T06ME00578

Parcel: 128120840


Addresses:

4917 E 17TH ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
05/21/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
05/16/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
CORRECTIONS HAVE NOT BEEN MADE
01/30/2007 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*
NOTE: YOUR A/C CONDENSATE DRAIN SHALL GRAVITY DRAIN TO WITHIN 6" OF FINISH GRADE BE SUPPORTED CORRECTLY ON ROOF AND IF PIPING PENETRATES THRU ROOF SHALL HAVE ROOF FLASHING. PVC PIPING TO BE PAINTED TO AVOID SUN DAMAGE.
01/25/2007 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*
SHALL INSULATE FITTINGS & ALL EXPOSED METAL DUCT IN ATTIC THAT IS NOT LINED.