Inspection History Details
Inspection Status: Partial Approval
Inspection History: MECHANICAL - FINAL
Permit Number - T06ME00522
Inspection Description - MECHANICAL - FINAL
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/05/2010 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection :* 1. GAS SHUT OFF VALVE TO UNIT IS ON WRONG END FLEX CONNECTION 2. UMT IS OVER FUSED 35 AMP MAX |
|
08/30/2006 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection :* THIS NOT AND A/C CHANGE OUT. 1. DUCTS IN CRAWL SPACE -- NEED INSULATION. 2. NEW GAS LINE - WHERE DID IT ORIGINATE? NEED PRESS. TEST ON GAS LINE, ORIGIN TO UNIT. 3. PAINT PVC AT UNIT (CONDENSATE) 4. NEED PERMIT FOR NEW A/C CIRCUIT. SEE WRITE UP FROM ELECT. CONTR. ON SHT. |