Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/28/2006 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 09/12/2006 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PROGRESSING 1. FURN. RM. DUCTS (FLEX) IN CONTACT WITH B-1 VENT PIPE. NEED CLEARANCE AS NECESSARY. 2. COMBUSTION/RELIEF AIR? 3. EAST SIDE UNIT, CONNECT/CORRECT ELEC. HI VOLTAGE CIR. INTO SWITCH, PROVIDE PROPER ACCESS. |
|
| 08/17/2006 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - GAS FLEX TO FURNACE CANNOT EXCEED 3' IN LENGTH & - CANNOT PENETRATE ANY PARTITION. - CAP OFF UNUSED GAS LINE UNDER THE PLATFORM. - CONNECT OVERFLOW SENSOR ON CONDENSATE PUMP. - PROVIDE A HOSE CLAMP ON PUMP. - PROVIDE A TRAP ON DRAIN LINE AS PER INSTALL INSTRUCTIONS. - PROVIDE 4" DOUBLE WALL VENT PIPE ON FURNACE & REDUCE TO 3" AT FURNACE. - TERMINATE WITH AN APPROVED ROOF JACK & CAP - DO NOT USE SHIPPING CRATES TO SUPPORT CONDENSORS - USE REDWOOD SLEEPERS & LEVEL CONDENSORS - CONDENSATE CANNOT DRAIN ONTO THE ROOF. - EXPOSED STAT WIRE MUST BE IN A CONDUIT. |