Inspection Status: Denied
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/08/2008 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* -- RE-ROUTE FLUE TO ALLOW PROPER CLEARANCE TO COMBUSTIBLES -- PROVIDE SCREWS WHERE SINGLE WALL FLUE MEETS DOUBLE WALL FLUE -- PROVIDE HOSE CLAMPS AT CONDENSATE PUMP DISCHARGE TUBING |
|
| 01/30/2008 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PROVIDE GROUNDED RECEPTACLE PROVIDE CORRECT MATERIAL FOR CONDENSATE PROVIDE OVERFLOW SENSOR ON SECONDARY DRAIN INSULATION ON DUCT SLEEVE? SECURE GAS PIPING SECURE VENT CONNECTION TO B-VENT EXTEND B-VENT TO 2' ABV AIR INTAKE OLON LEATHERS @ 326-5693 |