Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/24/2006 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 08/01/2006 | MECHANICAL - FINAL | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspectio ELEC. CONDUIT STILL NOT BLOCKED & CLAMPED AS NOTED ON PREVIOUS INSPECTION. CONDENSATE CANNOT TERMINATE INTO A HOLE DRILLED INTO A SEWER VENT. TERMINATE TO WITHIN 6" OF THE GROUND AS NOTED ON PREVIOUS INSPECTION. PAY A REINSPECTION FEE PRIOR TO NEXT INSPECTION. |
|
| 07/28/2006 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* ELEC. DISCONNECT OVERFUSED CONDENSATE CANNOT DRIP OUT OF THE SCUPPER. MUST GO TO WITHIN 6" OF THE GROUND. BLOCK & CLAMP ELEC. CONDUIT PAINT ALL EXPOSED PVC W/LATEX PAINT. |