Permit: T06ME00312

Parcel: 133041180


Addresses:

9236 E CALLE KUEHN

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
03/13/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
CORRECTIONS HAVE BEEN MADE
08/25/2006 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
CONDENSATE CANNOT TERMINATE INTO A SEWER VENT. MUST GO WITHIN 6" OF THE GROUND. BE SURE TO SLOPE DRAIN MIN. 1/8" PER FT. & USE A ROOF JACK AT ROOF PENETRATION. PROVIDE A ROOF JACK WHERE ELEC. CONDUIT PENETRATES THE ROOF. DO NOT USE WHITE WIRE FOR CONDUCTORS. TAPE BOTH ENDS BLACK. PROVIDE MIN. R-8 INSULATION IN EXPOSED DUCT ON ROOF. CIRCUIT BREAKERS MUST BE CUTLER HAMMER.