Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/15/2006 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* CORRECTIONS HAVE BEEN MADE |
|
| 05/10/2006 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* THE 3/8" I.D X 24" GAS FLEX CONNECTOR IS ONLY GOOD FOR 85,000 BTU. YOU NEED TO USE ONE THAT WILL PROVIDE AT LEAST 96,000 BTU. THIS WAS NOTED ON THE PREVIOUS INSPECTION. |
|
| 05/03/2006 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 3/8" I.D X 24" GAS FLEX CONNECTOR NOT ADEQUATE FOR 96,000 BTU FURNACE. SEE LISTING ON FLEX. PAINT ALL EXPOSED PVC & FITTINGS WITH LATEX PAINT. CONDENSATE CANNOT DRIP OVER THE EDGE OF THE ROOF. MUST TERMINATE WITHIN 6" OF THE GROUND IN AN AREA THAT CAN ABSORB THE WATER. DIVERT THE WATER AWAY FROM THE HOUSE. PROVIDE A ROOF JACK IF NECESSARY. WHEN YOU RESCHEDULE MECHANICAL, ALSO SCHEDULE YOUR PLUMBING FINAL. |