Inspection History Details
Inspection Status: Correction Required
Inspection History: VIOL - MEANS OF EGRESS
Case Number - T06FR02900
Inspection Description - VIOL - MEANS OF EGRESS
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/19/2006 | VIOL - MEANS OF EGRESS | Correction Required | TFC 1026.5 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises’ electrical supply. In the event of power supply failure, illumination shall be automatically provided from an emergency system for the following occupancies where such occupancies require two or more means of egress. ***Emergency egress lighting shall be comply with this section. {In stock room,West side electrical room}. |
|
12/18/2006 | VIOL - MEANS OF EGRESS | Correction Required | 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. ***Remove Keyed dead bolt from south east entrance/exit, and replace with a thumb turn dead bolt. ***Remove locking hardware from the outside of loss prevention doors. |
|
12/18/2006 | VIOL - MEANS OF EGRESS | Correction Required | TFC 1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists: [2.2]. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background. *** Place above-mentioned sign on or near the south east front door in an approved manner. |
|
12/18/2006 | VIOL - MEANS OF EGRESS | Correction Required | 1003.6 Means of egress continuity. The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter. The required capacity of a means of egress system shall not be diminished along the path of egress travel. ***Remove storage {Boxes} from egress path in break room. ***Clear exit area, and maintain it this way. {North west side of building, exterior exit}. ***Remove gas can and other storage from exit corridor. {By employee lounge.} |