Case: T06FR02798

Parcel: 12112358B


Addresses:

5118 E PIMA ST

Inspection Status: Approved

Inspection History: VIOL - EXPLOSIVES & FIREWORKS

Date Description Inspector Results Comments
12/27/2006 VIOL - EXPLOSIVES & FIREWORKS Approved Allowable quantities stocked.
11/29/2006 VIOL - EXPLOSIVES & FIREWORKS Violation Smokeless powder:
3306.5.1.1 Smokeless propellant. No more than 20
pounds (9 kg) of smokeless propellants, each in containers
of 1 pound (0.454 kg) or less capacity, shall be displayed
in Group M occupancies.
3306.5.1.3 Small arms primers. No more than 10,000
small arms primers shall be displayed in GroupMoccupancies.

***Check amount and provide documentation of amount to Fire Marshal.

***Comply with TFC 3306.5.2.1 Smokeless propellant, if quantity exceeds allowable amount on display- see attached Code.