Case: T06FR02565

Parcel: 12111190A


Addresses:

4826 E PIMA ST

Inspection Status: Approved

Inspection History: INSP - FULL

Date Description Inspector Results Comments
11/15/2006 INSP - FULL Approved all approved
09/13/2006 INSP - FULL Violation 1). Lock and hardware are too high. Shall follow IFC 1008.1.8.2 which states:

1008.1.8.2 Hardware height. Door handles, pulls, latches, locks and other operating devices shall be installed 34 inches (864 mm) minimum and 48 inches (1219 mm) maximum above the finished floor. Locks
used only for security purposes and not used for normal operation are permitted at any height.

2). In one year old room, there is a metal gate, which takes special knowledge to open, this shall be removed. IFC 1008.1.8

1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.

2). In the 2-year-old room, the door does not open freely and with ease. This shall be repaired. IFC 1027.2
3). Move smoke detector to ceiling in 2-year-old room. IFC 901.6
4). Repair hole in furnace room to 1 hour rated construction. IFC 703.1
5). Washing room, smoke detector is out of service, shall be repaired. IFC 901.6