Case: T06FR02369

Parcel: 133050710

Inspection Status: Approved

Inspection History: VIOL - MEANS OF EGRESS

Date Description Inspector Results Comments
09/18/2006 VIOL - MEANS OF EGRESS Approved
08/15/2006 VIOL - MEANS OF EGRESS Violation 26.TFC 1008.18 Door operation
No double key dead-bolt locks, no special knowledge needed,
no slide bolt locks. Only one unlatching device,
Except group R’s can have night latch, indicating dead bolt, or security chain on exits only.
1.MUST REMOVE THE DOUBLE KEYED DEAD BOLT FROM FRONT DOOR AND GATE. CAN REPLACE WITH THUMB LATCH TYPE LOCK
08/15/2006 VIOL - MEANS OF EGRESS Violation 31. TFC 1026.5 Emergecy ligting
Required in Group R if over 10, and must have 2 exits. Exception: If each sleeping room has a direct exit to the outside.
1.REPAIR THE EMERGENCY LIGHT IN HALLWAY