Inspection History Details
Inspection Status: Approved
Inspection History: VIOL - FIRE PROTECTION SYSTEMS
Case Number - T06FR02016
Inspection Description - VIOL - FIRE PROTECTION SYSTEMS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/27/2006 | VIOL - FIRE PROTECTION SYSTEMS | Approved | ||
06/16/2006 | VIOL - FIRE PROTECTION SYSTEMS | Violation | Class K Extinguisher: 904.11.5 Commercial cooking equipment. Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial-type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. ***A K class extinguisher shall be installed according to this code. A Re-inspection shall be on or before July 12th, 2006. Please call Inspector Cobb when items are abated. Thank You. |