Inspection History Details
Inspection Status: Approved
Inspection History: VIOL - BUILDING SVCS & SYSTEMS
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/11/2006 | VIOL - BUILDING SVCS & SYSTEMS | Approved | ||
| 06/14/2006 | VIOL - BUILDING SVCS & SYSTEMS | Violation | 20. TFC 605.5 Extension cords Grounds, used as permanent wiring, run under carpet, attached to walls can be replaced w/ power strip that has overcurrent protection 1. REMOVER EXSTENSION CORD FROM REFIG. AND PLUG DIRCTLY INTO OUTLET. SEE # 6 |
|
| 06/14/2006 | VIOL - BUILDING SVCS & SYSTEMS | Violation | 6. TFC 605.1 Abatement of electrical hazards Exposed electrical wires , covers, and panels locked. Undergroud romex can be above 7’ and not in conduit, if protected from UV light and damage. 1. REPLACE THE 2 PRONG ELECTRICAL OUTLET ON WEST WALL IN DINING ROOM, W/ A 3 PRONG TYPE. |