Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case: T06FR01416

Parcel: 11451141A

Inspection Status: Approved

Inspection History: VIOL - MEANS OF EGRESS

Date Description Inspector Results Comments
07/03/2006 VIOL - MEANS OF EGRESS Approved
05/23/2006 VIOL - MEANS OF EGRESS Violation Back door- Lock-latch, Key lock:
1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.
TFC 1008.1.8.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted.
***1. Remove lock latch hardware from back door and...
***2. Replace keyed lock with Thumb latch type lock on back door.
05/23/2006 VIOL - MEANS OF EGRESS Violation Exit signs over S and N patio doors leading to outside:
TFC 1011.1 Where required. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel.
***Place Exit signs, on over each of these two doors, in an approved manner.
05/22/2006 VIOL - MEANS OF EGRESS Violation Panic hardware on Exits:
1008.1.9 Panic and fire exit hardware. Where panic and fire exit hardware is installed, it shall comply with the following:
1. The actuating portion of the releasing device shall extend at least one-half of the door leaf width.
2. A maximum unlatching force of 15 pounds (67 N).
Each door in a means of egress from an occupancy of Group A or E having an occupant load of 100 or more and any occupancy of Group H-1, H-2, H-3 or H-5 shall not be provided with a latch or lock unless it is panic hardware or fire exit hardware.
***1. Install panic hardware on S and N doors leading from patio room to the outside. [no other locks are allowed on these doors].
***2. Remove "Exit" sign from over door leading to patio. [Door "A"]
***3. Door "A" may have a keyed lock on it for security, but it must be unlocked during business hours so...
***4. Place a sign on or over door stating " These doors shall remain unlocked while building is occupied"
***5. Remove lock latch hardware from back door and...
***6. Replace keyed lock with Thumb latch type lock on back door
05/22/2006 VIOL - MEANS OF EGRESS Violation Main entry, and patio entry:
TFC 1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists: [2.2]. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background.
*** Place above-mentioned sign on or near front door in an approved manner.
*** Place above-mentioned sign on or near the door leading out to patio [see below for explanation].