Inspection History Details
Inspection Status: Approved
Inspection History: VIOL - MEANS OF EGRESS
Case Number - T06FR01204
Inspection Description - VIOL - MEANS OF EGRESS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/24/2006 | VIOL - MEANS OF EGRESS | Approved | ||
05/05/2006 | VIOL - MEANS OF EGRESS | Violation | Rear doors- keyed locks: 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. ***Replace rear exit key locks with thumb bolt type. ***Remove bar hardware from shop door. |
|
05/05/2006 | VIOL - MEANS OF EGRESS | Violation | Exit signs: TFC 1011.1 Where required. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. ***Place exit sign over door leading to rear exit, as the actual exit cannot be seen from the main showroom. This sign may be unlit as the emergency lighting present will meet the requirement. |
|
05/05/2006 | VIOL - MEANS OF EGRESS | Approved | Exit blocked: TFC 1003.6 Means of egress continuity. The path of egress travel along a means of egress shall not be interrupted. ***Unblock rear exit, and keep it that way. Done while present 5/5/06 B.Cobb ***Re-arrange the bike rack so there is no impingement on the width of the exit access, or exit, or exit discharge. |
|
05/05/2006 | VIOL - MEANS OF EGRESS | Approved | Front door locked during Business hours: TFC 1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists: [2.2]. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background. Note: This means the door MUST BE unlocked as well... ***Keep door unlocked during business hours; will be checked periodically. THIS NOTICE SHALL SERVE AS A PRE-CITATION IN THE EVENT THE DOOR IS FOUND TO BE LOCKED DURING BUSINESS HOURS IN THE FUTURE. OR: Remove sign "This door to remain...." , remove hardware, and place items in front of it, thus eliminating the exit, as this is not a required exit. [Unlocked during inspection]- Thank you. |