Case: T06FR01066

Parcel: 11445262G

Inspection Status: Approved

Inspection History: VIOL - MEANS OF EGRESS

Case Number - T06FR01066

Inspection Description - VIOL - MEANS OF EGRESS

Inspection Status - Approved

Date Description Inspector Results Comments
08/18/2006 VIOL - MEANS OF EGRESS Approved
04/27/2006 VIOL - MEANS OF EGRESS Violation Doors: Back dock door:
TFC 1008.1.8.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted.
TFC 1003.6 Means of egress continuity.

*** Clear area leading to door and
*** Remove Bolt from door.
04/27/2006 VIOL - MEANS OF EGRESS Violation All doors with panic hardware:
1008.1.9 Panic and fire exit hardware. Where panic and fire exit hardware is installed, it shall comply with the following:
1. The actuating portion of the releasing device shall extend at least one-half of the door leaf width.
2. A maximum unlatching force of 15 pounds (67 N).
Each door in a means of egress from an occupancy of Group A or E having an occupant load of 100 or more and any occupancy of Group H-1, H-2, H-3 or H-5 shall not be provided with a latch or lock unless it is panic hardware or fire exit hardware.
***REMOVE all locks from these doors except the lock of the panic hardware itself.
04/27/2006 VIOL - MEANS OF EGRESS Violation Front door:
TFC 1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists: [2.2]. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background.
*** Place above-mentioned sign on or near front door in an approved manner.