Case: T06FR00774

Parcel: 13106031B


Addresses:

2545 S CRAYCROFT RD


Inspection Status: Approved

Inspection History: VIOL - MEANS OF EGRESS

Case Number - T06FR00774

Inspection Description - VIOL - MEANS OF EGRESS

Inspection Status - Approved

Date Description Inspector Results Comments
06/02/2006 VIOL - MEANS OF EGRESS Approved
04/12/2006 VIOL - MEANS OF EGRESS Violation Exit width and exit pathway:
TFC 1003.6 Means of egress continuity. The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in
this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter. The required capacity of a means of egress system shall not be diminished along the path of egress travel.
*** Keep entire "double door" assembly unlocked when building is occupied, and remove machine from in front of door immediately. See note above.
04/12/2006 VIOL - MEANS OF EGRESS Violation Emergency lighting:
TFC 1006.3 Illumination emergency power. In the event of power supply failure, an emergency electrical system shall automatically illuminate the area.
04/12/2006 VIOL - MEANS OF EGRESS Violation Concerning front doors:
TFC 1008.1.8.3 A readily visible durable sign [shall be] posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background.
*** Place above-mentioned sign on each front door in an approved manner.