Permit: T06EL02425

Parcel: 113043400

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
01/09/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
01/08/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
DOG IN YARD
LOCK UP DOG RECALL INSP.
01/02/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. REVISE PERMIT TO SHOW THIS IS A DUPLEX WITH SEPARATE UNIT NUMBERS AND METERS AND INSTALL UNIT NUMBERS ON UNITS.
2. USE A LISTED GUY KIT FOR MAST SUPPORT AND SECURE IT INTO STRUCTURE - NOT SHEETING NEC 230.28
3. FEEDER ENTERING W.P BOX ABOVE SERVICE NEEDS PROPER CONNECTOR - NEC 314
4. SECURE GROUNDING ELECTRODE CONDUCTOR TO STRUCTURE AND/OR BURY 12" MINIMUM - NEC 250.54 & 300.5