Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/15/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. CALL TEP TO REMOVE LOCK FROM DISCONNECT 2. LABEL SERVICES #1 & #2 USE PERMANENT LABEL 3. ROMEX WIRING FROM SERVICE DISCONNECT INTO CARPORT FOR LIGHT & OUTLETS, NOT DONE PER CODE. REMOVE OR OBTAIN QUALIFIED ELECTRICIAN TO WIRE PER CODE. 4. COOLER TO HAVE WEATHERPROOF OUTLETS/RECEPTACLES AND COVERS FOR CORDS TO PLUG INTO 5. WATER HTR. NOT LISTED FOR CORD & PLUG MUST BE HARDWIRED. 6. OUTSIDE RECEPTACLE & LIGHT BY BACK DOOR MUST BE RATED FOR OUTDOORS 7. INSTALL MISSING COVERS FOR LIGHT SWITCHES/RECEPTS AND REPAIR BROKEN ONES. 8. INSTALL SMOKE DETECTORS IN SLEEPING AREAS. |