Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T06EL02349
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/22/2006 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 12/13/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* |
|
| 12/12/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. MARKING LABEL TO BE PERMANENT METAL ADDRESS LABEL 2. USE APPROVED HANDLE TIE 3. BREAKER TO BE LISTED FOR USE BY MANUFACTURE 4. INTERIOR PANEL IS A 2 WIRE UNGROUNDED SYSTEM 5. SHEETMETAL SCREWS NOT ALLOWED FOR GROUNDING. |
|
| 12/11/2006 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. WATER HEATER NOT ALLOWED TO BE CORD & PLUG CONNECTED. 2. INTERIOR SUB-PANEL IS AN UNGROUNDED SYSTEM. WE HAVE GROUNDED RECEPTACLS CONNECTED. ONLY ONE NEUTRAL TO A LUG TERMINATION. 3. PLEASE UNLOCK EXTERIOR SUB-PANEL AND LABEL. 4. RECONNECT GROUND WIRE. |