Permit: T06EL02289

Parcel: 10709079C

Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Permit Number - T06EL02289

Inspection Description - ELECTRIC - FINAL

Inspection Status - Denied

Date Description Inspector Results Comments
03/23/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
THIS IS A REGULAR HOUSE EXTENSION CORD
IT CANNOT BE USED TO CONNECT AN RV
THE CORD CAP TO RV IN IS WRONG
03/12/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
ENDS OR CORDS NEED TO BE MOLDED
12/13/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. NEED TO HAVE QUALIFIED ELECTRICAL CONTRACTOR MAKE CORRECTIONS - CORD NEEDS TO BE PROPERLY SIZED AND HAVE FACTORY MOLDED ENDS/WEATHER TIGHT - 35 AMP 120V
ALSO, NEED SCREW FOR DEAD FRONT COVER @ SERVICE
11/30/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PEDESTAL IS 30 AMPS LARGE FEMALE CONNECTION REQUIRED TO HOOK UP TO THIS PEDESTAL.
2. CORD TO TRAILER IS #12 FOR 20 AMPS AND DOES NOT FIT INTO PEDESTAL.

NOTE: END CAPS OR WIRE TO TRAILER SHOW EXPOSED WIRES.
11/29/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
There is no access to the site.| 920*
- UNIT LOCKED, NOT CONNECTED TO SERVICE PEDESTAL
- RECALL INSP. LEAVE MESSAGE WITH ANY SPECIAL INSTRUCTIONS.