Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - SERVICE UPGRADE
Permit Number - T06EL02273
Inspection Description - ELECTRIC - SERVICE UPGRADE
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/16/2007 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. RISER CONDUIT BRACE MUST BE LISTED KIT, HOMEMADE OUT OF SMASHED EMT CONDUIT NOT APPROVED. 2. PROVIDE LADDER FOR J-BOX INSPECTION ABOVE SERVICE, USE PROPER COVER. 3. SUPPORT #6 GROUND WIRE TO WALL, BURY WIRE ALONG BUILDING OR SUPPORT TO WALL BETWEEN SERVICE & WATER HEATER. 4. INSTALL SEALING LOCKNUT AT SIDE TERMINATION OF PANEL. 5. NO POWER CLEARANCE UNTIL UNSAFE WIRING AROUND HOUSE UP TO CODE. EXPOSED ROMEX FOR SECURITY LIGHTING. ALSO, PREVIOUS PERMITS TO BE SATISFIED, SEE LOCKS, HOLDS. 6. INSTALL PERMANENT ADDRESS LABEL ON SERVICE. |