Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/11/2007 | ELECTRIC - FINAL | Approved | ||
| 01/08/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NEED TO INSPECT NEW CIRCUITS ADDED INSIDE IN ORDER TO FINAL. |
|
| 12/18/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* SEE WRITE UP FOR #1 |
|
| 11/29/2006 | ELECTRIC - FINAL | Not ready for Inspection | CALL FOR FINAL ONCE ENERGIZED | |
| 11/22/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The service is not per code.| 210* 1) SERVICE DROP NEEDS TO ATTACH TO MINIMUM 2" RIGID MAST 2) MOVE METER LUGS TO OVER HEAD SERVICE POSITION 3) BOND ALL PIPING SYSTEMS TO SERVICE (DRAIN, SEPERATE WATER AND GAS) 4) HAVE TO HIGH BREAKER FOR LIGHTING CKT 5) SEAL ROOF FLASHINGS 6) ADD ALL NEW WIRING TO PERMIT FOR INSPECTION 7) INSTALL ADDRESSES ON UNITS |
|
| 11/16/2006 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* CHECK TO MAKE SURE ADDRESS AND SERVICE LABEL ARE CORRECT. |