Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/08/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) CONDITION OF SERVICE EQUIPMENT IS DETERIORATED. WE ALSO HAVE NUMEROUS CODE VIOLATIONS 2) LABELS TO BE SCREWED OR RIVITED TO EQUIPMENT |
|
| 11/02/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PLEASE REMOVE ZIP CORD WIRING 2) WE HAVE A BURNT AND DAMAGED RECEPTACLE 3) ATTACH BOXES TO WALL 4) CLEAN EXCESS PAINT OUT OF DEVICES 5) REPLACE BROKEN FACE PLATE 6) TAPE IS NOT AN APPROVED HANDLE TIE 7) LABEL BREAKERS 8) BOXES TO BE LISTED FOR WET LOCATION, ALSO FITTINGS 9) CONDUIT AND LB SEPERATED 10) EQUIPMENT AT SERVICE IN DETERIORATING CONDITION 11) A PERMANENT METAL ADDRESS LABEL IS NEEDED 12) KITCHEN RECEPTACLE TO BE GFCI PROTECTED 13) NEON INTERIOR PORATBLE SIGN NOT LISTED 600.3 |