Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/15/2006 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 11/06/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PLEASE VERIFY DEVICES ARE FOR USE WITH ALUMINUM CONDUCTORS. 2. PROPERLY TERMINATE CONDUCTORS TO DEVICE TERMINALS. 3. FINISH PROVISIONS ITEMS 2, 4, 5, 6, 8 & 9 |
|
| 10/31/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. CLEAN EXCESS PAINT OUT OF RECEPTACLES OR REPLACE. 2. PROPERLY WIRE COOLER -- CORDS NOT TO BE SPLICED OR RUN THROUGH CEILING. 3. KITCHEN AND BATHROOM RECEPTACLES TO BE GFI PROTECTED. 4. FIXTURES ARE NOT PROPERLY MOUNTED TO BOXES. 5. WE HAVE UNSAFE WIRING AT SUB-PANEL 6. PROTECT CABLES ENTERING SUB-PANEL 7. SMOKE DETECTORS NEEDED IN BEDROOMS ALSO 8. A PERMANENT ADDRESS LABEL IS NEEDED FOR PEDESTAL/METER. 9. HAVE QUALIFIED ELECTRICIAN PERFORM WORK. |